Choose a calculation
The overview requires View formulations permission. Browsing it does not enable calculations in chat. Batch-tool execution retains the organization’s activation and audience settings. Property calculations run in the Studio and, where enabled and authorized, through Herman or the formulation MCP tools.
Read the result before using the number
Property results identify their source, method, confidence, coverage, and any missing inputs or assumptions. A result may be measured, calculated, estimated, or missing. When a blend measurement is supplied, the reported source identifies it as measured. Coverage matters: some mixing rules calculate from the ingredients with usable data and normalize their weights over that subset. A value with incomplete coverage does not describe the entire formula. HLB coverage is measured over the surfactant portion. Other methods may return no value when required inputs are absent. The model group contains both component-data methods and optional prediction methods. A listed model can be disabled or unavailable; check its status and the result notes. A model name in the catalog is not a promise that it can run for every ingredient or organization.Flash point and auto-ignition estimates require confirmation by test. Surface tension, solubility, and shelf-life projections depend on the stated assumptions. These calculations do not establish regulatory compliance, full compatibility, or product stability.
Symbols and units
Unless a section says otherwise, equations below assume complete usable input data.
Temperature in a reciprocal-temperature equation is in kelvin:
T(K) = T(°C) + 273.15. Use ingredient measurements at compatible conditions; the batch conversion tools do not infer a temperature correction.
Batch and conversion tools
These five tools use your supplied quantities and assays. They do not infer ingredient properties from a material name.Scale a batch
For target batch massB and ingredient percentage pᵢ:
Balance active content
For target batch massB, stock activity a_stock, diluent activity a_diluent, and target activity a_target:
Mass conversion
The tool uses decimal conversion factors between g, kg, lb, US ton, and metric ton:Mass and volume conversion
Dynamic and kinematic viscosity conversion
Mixing rules: seven property calculators
Example: equal masses of two ingredients with densities of 1.0 and 0.8 g/mL give
1 / (0.5/1.0 + 0.5/0.8) = 0.8889 g/mL. An arithmetic mean of the densities would use the wrong weighting basis.
Equation-based properties: eleven calculators
Dynamic and kinematic blend viscosity
Both properties offer Refutas and Arrhenius log-mixing methods. Refutas is the default. Supply ingredient viscosity and density as needed to convert between dynamic and kinematic values. Refutas operates on kinematic viscosity in cSt:νᵢ + 0.8 must exceed 1. Arrhenius log-mixing operates on positive dynamic viscosities:
Vapor pressure
The Raoult–Dalton calculation uses ingredient vapor pressures and molecular weights:Flash point
The default Liaw mixing rule solves for temperatureT:
Initial boiling point
The bubble-point calculation solves:Freezing point depression
HLB of the surfactant system
Settling velocity and time
Stokes’ law provides two outputs:d and fill height H in metres, densities in kg/m³, and viscosity in Pa·s. The Studio accepts particle diameter in µm and fill height in cm, and performs the conversions. Velocity is reported in µm/s and time in hours.
The calculation needs solid and fluid ingredient lines with densities, particle diameter, and blend dynamic viscosity. It calculates particle and fluid densities separately using inverse mass-weighted density. A negative velocity indicates creaming; matching densities produce no settling-time value.
Assumptions are dilute, spherical, non-interacting particles in a Newtonian fluid. The estimate does not capture flocculation or a yield-stress structure.
Projected shelf life: Q10 and Arrhenius
Both calculators require an accelerated-stability observation: days passed at the accelerated temperature, and the intended storage temperature.Ea in kJ/mol for the second. The implementation uses R = 8.314 J/(mol·K) and 30-day months. Both assume one dominant degradation pathway. They extrapolate an observation; they do not establish shelf life from the recipe alone.
Check the scenario values before running a calculation. The current defaults are 25 °C for the scenario temperature, 10 cm for fill height, Q10 of 2, and activation energy of 83 kJ/mol. Defaults are assumptions, not measurements of your product.
Example: 30 days at 40 °C projected to 20 °C with Q10 = 2 gives 30/30 × 2² = 4 months under that assumption.
Models and component estimates: four calculators
Surface tension
The component-data method combines pure-component surface tensions, normally using mole fractions:Solubility risk
The Chemprop aqueous-solubility method compares each assessed non-water component’s concentration with its predicted solubility:Auto-ignition temperature
Hildebrand solubility parameter
The implementation estimates each component’s cohesive-energy parameter and then mass-weights the component values:ΔHvap in kJ/mol, molecular weight in g/mol, and density in g/mL. Here Vm is cm³/mol, R = 0.008314 kJ/(mol·K), and the implementation uses 298.15 K. Output is MPa½.
This is a low-confidence component estimate. The method ignores blend interactions and does not provide Hansen partial parameters or a compatibility verdict.
When a result is missing or unexpected
- Check the formula’s wt% values and the units of each ingredient input.
- Check temperature, particle size, fill height, or stability-test conditions required by the selected method.
- Inspect the reported method, including any fallback, and review coverage and missing ingredients.
- Check whether an optional prediction model is enabled and available for the inputs.
- Compare the result with suitable blend measurements before using it for a formulation decision.